Note 1) The minimum bending radius means the value measured by the method shown in the figure at the right at the temperature of 20°C when the tube is bent. The minimum
bending radius assumes static piping. If the tube is used in a moving part, provide extra length to the tube. Check the bending radius recommended by the flexible
protection tube manufacturer for sure if the tube is used in the flexible protection tube.
Note 2) Not clear, but opaque due to material.
Model
Specifications
TUZ1208
쎲 — 20 m roll 쏔 — 100 m roll
Model
12
8
TUZ1065
10
6.5
TUZ0805
8
5
TUZ0604
6
4
TUZ0425
4
2.5
Tubing O.D. (mm)
Tubing I.D. (mm)
Black (B)
White (W)
Red (R)
Blue (BU)
Yellow (Y)
Green (G)
Fluid
Burst pressure
Min. bending radius (mm)
Operating temperature
Material
Applicable fittings
Max. operating
pressure
20°C
60°C
Air
0.8 MPa
0.4 MPa
Refer to the burst pressure characteristics curve.
–20 to +60°C
Special polyurethane
10 15 20 27 35
One-touch fittings KQ/KJ series,
Insert fittings KF series, Stainless steel 316 insert fittings KFG series,
Miniature fittings M/MS series (hose nipple type)
How to Order
Wear Resistant Tubing
Series TUZ
TUZ0425 BU 20
Tubing model
Model
TUZ0425
TUZ0604
TUZ0805
TUZ1065
TUZ1208
O.D. x I.D. (mm)
4 x 2.5
6 x 4
8 x 5
10 x 6.5
12 x 8
Color
Symbol
B
W
R
BU
Y
G
Color
Black
White
Red
Blue
Yellow
Green
Length per roll
Symbol
20
100
Length
20 m roll
100 m roll
Bend the tube into U-form at the
temperature of 20°C. Fix one end
and close loop gradually. Measure
2R when the tube breaks or is cru-
shed.
How to Calculate Minimum Bending Radius
Burst Pressure Characteristics Curve and Operating Pressure
Temperature (°C)
0–20
4.0
3.0
2.0
1.0
0
Pressure (MPa)
20 40 60
Burst pressure
Fixed end
2R
Maximum operating pressure
1