0
1
8
9
14
15
7
6
SS5Q SB3
Nil
N
Positive common
Negative common
SI unit output polarity
Valve stations
Note) Max. 16 stations
(Special wiring
specifications)
01
08
Symbol
1 station
8 stations
Stations
Double
Wiring
Note
1 08 D
Manifold series
1
SQ1000
DIN rail mounting
Nil
02 to 16
(1)
B
(2)(3)
K
(4)
N
R
S
None
DIN rail length specified
Back pressure check valve
Special wiring specifications (Except double wiring)
With name plate (Side ported only)
External pilot specifications
Built-in silencer, direct exhaust
Option
Note 1) Specify DIN rail length with “D” at the end.
(Enter the number of stations inside .)
The number of stations that may be displayed
is longer than the manifold number of stations.
Example: -D09
Note 2) When “-B” is selected, a back pressure check
valve is included in all stations of the manifold.
If the back pressure check valve is used only
for the station that need it, then specify the
station location in the manifold specification.
(“-B” is not necessary)
Note 3) Since 4 port specification valves (5 (R1) and 3
(R2) are common) are used, back pressure
cannot be prevented with dual 3 port valves.
Note 4) Specify “-K” for wiring specification for cases
below.
- All single wiring
- Single and double mixed wiring
- When there are stations which do not require
wiring (e.g. single SUP spacer), specify the
wiring specification in the manifold specifica-
tion so that the number of the solenoids is
16 maximum. (Standard wiring specification
is double wiring)
Note 5) For specifying two or more options, enter
them alphabetically.
Example: -BKN
∗ Refer to pages 42 to 46 and 52 to 54 for manifold
option parts.
Nil
00T
1(P), 3(R) port, One-touch
fittings for ø8
1(P), 3(R) port, One-touch
fittings for ø5/16"
1(P), 3(R) port size
Nil
Q
—
CE compliant
CE compliant
How to Order Manifold Assembly
Example
Symbol SI Unit Specifications SI unit part no. Page
Best Pneumatics
No.1
EX510-S002B
EX510-S102B
Positive common (NPN)
Negative common (PNP)
Nil
N
SI Unit Part No.
EX510 Gateway-type Serial Transmission System
Plug-in Unit
Series SQ1000
How to Order Manifold
Refer to Best Pneumatics No.1 and the Operation Manual
for the details of EX510 gateway-type serial transmission system.
Please download it via our website, http://www.smcworld.com
1 2 3 4 5 6 7 8
Stations
2 position double (24 VDC)
SQ1230D-51-C6 (3 sets)
2 position single (24 VDC)
SQ1130-51-C6 (4 sets)
Manifold base (8 stations)
Cylinder port fitting
C6: One-touch fittings for ø6
Blanking plate
SSQ1000-10A-3 (1 set)
D side
U side
Add the valve and option part number under the manifold base part number.
When entry of part numbers becomes complicated, indicate by the manifold
specification sheet.
SS5Q13-SB08-D ······ 1 set
(SB kit 8-station manifold base part no.)
∗ SQ1130-5-C6 ··········· 4 sets (Single type part no.)
∗ SQ1230-5-C6 ··········· 3 sets (Double type part no.)
∗ SSQ1000-10A-3 ······ 1 set (Blanking plate part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the solenoid valve, etc.
Enter in order starting from the first station on the D side.
1
[Option]