y Electrical entry
L
LO
G
L-type plug connector, with 0.3 m lead wire,
with light/surge voltage suppressor
L-type plug connector, without connector,
with light/surge voltage suppressor
Grommet, with 0.3 m lead wire
(Latching/AC type: Not applicable)
u Manual override
Note 4)
Nil
B
Non-locking push type
Latching type: Push-locking type
Locking type (Q1/Q2/N1/N2: Not applicable)
Note 4) Latching type supply valve: Available in “Nil” only.
In this case, the supply valve and release valve come
with a push-locking type.
i Vacuum pressure switch suction filter
Note 5)
EA
EB
EC
EE
FA
FB
FC
FE
F
0 to –101 kPa/NPN open collector 2 outputs, with suction filter
0 to –101 kPa/PNP open collector 2 outputs, with suction filter
0 to –101 kPa/NPN open collector 1 output + analog voltage, with suction filter
0 to –101 kPa/PNP open collector 1 output + analog voltage, with suction filter
100 to –100 kPa/NPN open collector 2 outputs, with suction filter
100 to –100 kPa/PNP open collector 2 outputs, with suction filter
100 to –100 kPa/NPN open collector 1 output + analog voltage, with suction filter
100 to –100 kPa/PNP open collector 1 output + analog voltage, with suction filter
Suction filter only
!0 Vacuum pressure switch
lead wire specifications
Nil
G
Without connector
Lead wire with connector
(Lead wire length 2 m)
With connector cover
!1Check valve
Note 8)
Nil
K
None
With check valve
!3 Fitting (P port)
Note 9)
Symbol
Nil
0
2
3
5
Applicable tubing O.D.
Without port
Without fitting (M5 x 0.8)
ø4 (Straight)
ø6 (Straight)
ø4 (Elbow)
Part no.
—
—
KJS04-M5
KJS06-M5
KJL04-M5
Object spec.
Manifold
Single unit
!4 CE compliant
Nil
Q
—
CE marked
Note 9) For filter only (Without vacuum pressure switch)
When neither V port fitting nor P port fitting are needed, enter nothing or –00 in the dotted
line above “How to Order”.
q
Cannot be used for vacuum retention.
w
Use a release valve. (Without a release valve, a
workpiece may not be released.)
Warning
Note 8) The check valve has a function to prevent
the exhaust air from the silencer overflowing
to the vacuum port side when a manifold is
used. However, depending on usage
conditions, it does not always suppress air
overflow to the desired extent. During usage,
please inspect thoroughly with actual
machine.
Also, in order to completely prevent the
overflow of exhaust air, leave plenty of
space between the check valve unit and
adjacent ejector to avoid interference from
the ejector’s exhaust unit.
o Vacuum pressure switch
unit specifications
Nil
M
P
With unit switching function
Note 6)
Fixed SI unit
Note 7)
With unit switching function
Note 6)
(Initial value psi)
Note 6) Under the New Measurement Law, sales of
switches with the unit switching function are not
allowed for use in Japan.
Note 7) Fixed unit: kPa
Note 5) The filter included in this product is of an simple type, and will become clogged quickly in environments with
high quantities of dust or particulates. Please make additional use of an air suction filter of the ZFA, ZFB or
ZFC series.
The filter case of this suction filter is made of nylon. Contact with alcohol or similar chemicals may cause it to be
damaged. Also, do not use the filter when these chemicals are present in the atmosphere.
Warning
!2 Fitting (V port)
Note 9)
Symbol
0
1
2
3
4
5
Part no.
Vacuum pressure switch
VVQ1000-50A-M5
VVQ1000-50A-C3
VVQ1000-50A-C4
VVQ1000-50A-C6
VVQ1000-F1-LC3
VVQ1000-F1-LC4
Filter only
—
KJS23-M5
KJS04-M5
KJS06-M5
KJL23-M5
KJL04-M5
Applicable tubing O.D.
Without fitting (M5 x 0.8)
ø3.2 (Straight)
ø4 (Straight)
ø6 (Straight)
ø3.2 (Elbow)
ø4 (Elbow)
Note) CE compliant: For DC only.
2
Space Saving Vacuum Ejector Series ZQ