Bracket
With suction
filter
Note 10)
Note 10)
With suction
filter
Note 10) The filter included in this product is of an simple type, and will become
clogged quickly in environments with high quantities of dust or
particulates. Please make additional use of an air suction filter of the
ZFA, ZFB or ZFC series.
Note 11) Be sure to hold the filter case when connecting and disconnecting the
tube for the elbow type.
C2
C4
N1
N3
L2
L4
LN1
LN3
Straight ø2 mm one-touch fitting
Straight ø4 mm one-touch fitting
Straight ø1/8" one-touch fitting
Straight ø5/32" one-touch fitting
Elbow ø2 mm one-touch fitting
Elbow ø4 mm one-touch fitting
Elbow ø1/8" one-touch fitting
Elbow ø5/32" one-touch fitting
Metric
size
Inch
size
Metric
size
Inch
size
Note 12) When multiple options are selected, state them in alphabetical
order.
B
K
With bracket for single unit
(Enclosed with the product
for shipment without
being assembled)
Screwdriver handling type
vacuum break needle
Without option
Nil
G
Without lead wire with connector (No need to specify for pressure sensor type. )
Lead wire with connector and connector cover, Lead wire length 78.7 inch (2 m)
Nil
The filter case of this suction filter is made of nylon. Contact with alcohol
or similar chemicals may cause it to be damaged. Also, do not use the
filter when these chemicals are present in the atmosphere.
Warning
Type
Symbol
Pressure range psi (kPa)
Specifications
Note 7) Only the lead wire length 118 inch (3 m) is available for the pressure sensor.
Note 8) The unit switching function is not available in Japan due to a new measurement law.
Note 9) Fixed unit: kPa
Vacuum (V) Port
Note 11)
Option
Note 12)
Lead Wire with Connector for Vacuum Pressure Switch
Pressure Sensor/Vacuum Pressure Switch Specifications
Nil
P1
P3
EA
EAM
EAP
EB
EBM
EBP
FA
FAM
FAP
FB
FBM
FBP
Without pressure sensor/vacuum pressure switch
Pressure
sensor
Vacuum
pressure
switch
0 to –14.6 (0 to –101)
–14.5 to 14.5 (–100 to 100)
NPN
2 outputs
PNP
2 outputs
NPN
2 outputs
PNP
2 outputs
Output: 1 to 5 V, accuracy: ±2% F.S. or less
Note 7)
Output: 1 to 5 V, accuracy: ±2% F.S. or less
Note 7)
With unit switching function
Note 8)
SI unit only
Note 9)
With unit switching function [Initial value psi]
Note 8)
With unit switching function
Note 8)
SI unit only
Note 9)
With unit switching function [Initial value psi]
Note 8)
With unit switching function
Note 8)
SI unit only
Note 9)
With unit switching function [Initial value psi]
Note 8)
With unit switching function
Note 8)
SI unit only
Note 9)
With unit switching function [Initial value psi]
Note 8)
0 to –14.5 (0 to –101)
–14.5 to 14.5 (–100 to 100)
E쏔/F쏔: Vacuum pressure switch
P쏔: Pressure
sensor
2
Compact Vacuum Unit
Series ZB