How to Order
23IDHA 6
10IDH 6
Size
4
6
Rated air flow capacity
14.1 scfm (400 L/min [ANR])
21.2 scfm (600 L/min [ANR])
Air compressor
size
3.7 kW
5.5 kW
Size
Voltage
Symbol
10
20
23
Voltage
Single-phase 100 VAC (50/60Hz)
Single-phase 200 VAC (50/60Hz)
Single-phase 230 VAC (50/60Hz)
Specification
For use in Japan
For use in Europe and Southeast Asia
Combination of built-in products
Nil
A
B
Regulator
¡
¡
¡
Filter
햲
(AMH)
¡
¡
—
Filter
햳
(AME)
¡
—
—
Symbol
Filter
햲
(AMH)
Filter details
Micro mist separator with pre-filter
·
Nominal filtration rating: 0.01 µm (99.9% filtration efficiency)
·
Outlet oil mist concentration: MAX. 0.1 mg/m
3
[ANR] (≈0.08 ppm)
Filter
햳
(AME)
Super mist separator
·
Nominal filtration rating: 0.01 µm (99.9% filtration efficiency)
·
Outlet oil mist concentration: MAX. 0.01 mg/m
3
[ANR] (
≈
0.008 ppm)
·
Outlet oil mist concentration: Particles of 0.3 µm or more: 3.5
particles/L [ANR] or less
Descripiton
Option
Nil
E
None (Standard)
Auto drain normally closed
Construction (Pneumatic/Refrigerant Circuit)
Hot and humid air entering this product is cooled down by the
cooler. The moisture condensed at this time is separated by the
drain separator and exhausted automatically. The pressure of the
dry air is adjusted by the regulator, and oil mist and solid particles
are separated by the micro mist separator with pre-filter and super
mist separator.
Note)
The temperature of the dry and high purity air
Note)
is adjusted by the heater and supplied to the outlet side.
Note) The type without filter is not applicable.
Pneumatic circuit
The HFC gas contained in the refrigerant circuit is compressed
by the compressor, and cooled and liquefied by the condenser.
When passing through the capillary tube, the HFC gas is
regulated and its temperature decreases. While passing through
the cooler part, it evaporates rapidly, taking the heat from the
compressed air, and is sucked in by the compressor. The
capacity regulating valve opens when the compressed air has
been cooled sufficiently, and prevents condensed water from
being frozen by excessive cooling.
Refrigerant circuit
Drain outlet
Air pressure gauge
Heater
Super mist separator
Note)
Micro mist separator with pre-filter
Note)
Evaporation
thermometer
Pressure switch
Cooler
Capacity regulating valve
Compressor for
refrigeration
Condenser
Fan motor
Capillary tube
Compressed air outlet
Compressed air inlet
Drain separator
Regulator
The auto drain which exhausts dehumidified drainage and the
auto drain on the built-in filter are changed to the "normally
closed" specification. Recommended for small flow rate (100
to 150 L/min).
Auto drain normally closed
Option symbol
E
Optional Specifications
For use in Europe
and Southeast Asia
For use in
-DSDQ
3
Refrigerant R134a
(
HFC
)
Series IDH 첸
RoHS