Standard Strokes
Bore size
(mm)
20, 25
32
40, 50, 63
80, 100
Stroke
(mm)
5
10 15 20 25 30 35 40 45 50
55 60 65 70
75 100
80 85 90 95
Intermediate stroke [XC63]
(Built-in spacer type)
Intermediate stroke [XC63]
(Built-in spacer type)
: Standard stroke (dedicated cylinder tube)
: Intermediate stroke XC63 (built-in spacer type)
Made to Order specifications
(For details, refer to pages 275 to 278)
Symbol Specifications
Change of rod end shape
Compatible with CHQHB series (14 MPa)
Intermediate stroke type (Built-in spacer type)
With air release valve
-XA
-XC61
-XC63
-XC64
Action
Fluid
Nominal pressure
Proof pressure
Maximum allowable pressure
Minimum operating pressure
Ambient and fluid temperature
Piston speed
Cushion
Rod end thread
Stroke length tolerance
Mounting type
Bore size (mm)
Specifications
Double acting/Single rod
Hydraulic fluid
10 MPa
15 MPa
13 MPa
0.3 MPa
Without auto switch: –10° to 80°C
With auto switch: –10° to 60°C
8 to 100 mm/s
None
Female thread, Male thread
mm
Basic type (through hole), Foot type
Note) Refer to page 214 for definitions of terms related to pressure.
+0.8
0
20 25 32 40 50 63 80 100
Manufacture of Intermediate Stroke Cylinders
[XC63] (Built-in spacer type)
Intermediate strokes in 5 mm increments can
be manufactured by installing spacers inside
standard stroke cylinders. (Except ø20, ø25)
55, 60, 65 and 70 mm stroke cylinders have
the same overall length as a 75 mm stroke
cylinder, and 80, 85, 90 and 95 mm stroke
cylinders have the same length as a 100 mm
stroke cylinder.
Refer to the Made to Order Specifications on
page 277 for the ordering procedure.
∗ Consult with SMC.
Hydraulic Fluid Compatibility
Standard mineral hydraulic fluid
W/O hydraulic fluid
O/W hydraulic fluid
Water/Glycol hydraulic fluid
Phosphate hydraulic fluid
Compatibility
Compatible
Compatible
Compatible
∗
Not compatible
Hydraulic fluid
265
JIS Standard Compact Hydraulic Cylinder: 10 MPa
CH KD Series