686
* Refer to page 690 for dimensions and part numbers of the option. Refer to page 688 for
dimensions of the rod boot.
Accessories
Symbol
Standard Stroke
(kg)Weight
* Strokes longer than the standard stroke are made-to-order products.
CE2 Series
Calculation example: CE2L40-100
¡Basic weight
…………………
2.37 (Foot type, ø40)
¡Additional weight
……………
0.22/50 stroke
¡Cylinder stroke
………………
100 stroke
2.37 + 0.22 x 100/50 = 2.81 kg
Cylinder Specifications
Sensor Specifications
* Be aware of the constraints in the allowable kinetic energy.
Note) Digital error under Controller (CEU2), Counter (CEU5) is included. Besides, the whole accuracy after mounting on an equipment
may be varied depending on the mounting condition and surroundings. As an equipment, calibration should be done by customer.
Model
Rod Boot Material
* Maximum ambient temperature for the rod boot itself.
Bore size (mm)
40 50 63 80 100
Basic weight
Basic type 2.18 3.39 5.29 8.66 12.09
Foot type 2.37 3.61 5.63 9.33 13.08
Flange type 2.55 3.84 6.08 10.11 14.01
Single clevis type 2.41 3.73 5.92 9.77 13.87
Double clevis type 2.45 3.82 6.08 10.06 14.39
Trunnion type 3.63 3.92 6.18 10.36 14.49
Additional weight per
each 50 mm of stroke
Aluminum
tube
Mounting
bracket
0.22 0.28 0.37 0.52 0.65
Accessory bracket
Single knuckle 0.23 0.26 0.26 0.60 0.83
Double knuckle 0.32 0.38 0.38 0.73 1.08
Knuckle pin 0.05 0.05 0.05 0.14 0.19
Bore size (mm)
Standard stroke (mm) Range of manufacturable stroke
*
Without rod boot With rod boot Without rod boot With rod boot
40
25 to 850 25 to 700 Up to 1200 Up to 950
50
25 to 800 25 to 650 Up to 1150 Up to 900
63
25 to 800 25 to 650 Up to 1150 Up to 900
80
25 to 750 25 to 600 Up to 1100 Up to 900
100
25 to 750 25 to 600 Up to 1100 Up to 850
Symbol
Rod boot material
Maximum ambient temperature
J
Nylon tarpaulin 60°C
K
Neoprene cross 110°C
*
Series
Type Action
Bore size
(mm)
Lock
action
CE2
Non-lube
Double
acting
40, 50, 63
80, 100
Spring and
pneumatic lock
Cable
ø7, 6 core twisted pair shielded wire (Oil, Heat and Flame resistant cable)
Maximum transmission distance
20.5 m (when using SMC cable while using controller or counter)
Position detection method Magnetic scale rod/Sensor head <Incremental type>
Magnetic field resistance 14.5 mT
Power supply 10.8 to 26.4 VDC (Power supply ripple: 1% or less)
Current consumption 50 mA
Resolution 0.1 mm/pulse
Accuracy
±0.2 mm
Note)
Output type Open collector (Max. 35 VDC, 80 mA)
Note)
Output signal A/B phase difference output
Insulation resistance
50 MW or more (500 VDC measured via megohmmeter) (between case and 12E)
Vibration resistance
33.3 Hz, 6.8 G 2 hrs. each in X, Y directions 4 hrs. in Z direction based upon JIS D 1601
Impact resistance 30 G, 3 times at X, Y, Z
Enclosure IP65 (IEC standard) Except connector part
Extension cable (Option) 5 m, 10 m, 15 m, 20 m
Bore size (mm)
ø
40 ø50 ø63 ø80 ø100
Fluid Air (Non-lube)
Proof pressure
Drive 1.5 MPa
Brake 0.75 MPa
Maximum
operating pressure
Drive 1 MPa
Brake 0.5 MPa
Minimum
operating pressure
Drive 0.1 MPa
Brake 0.3 MPa
Piston speed 50 to 500 mm/s
*
Ambient temperature 00 to 60°C (No freezing)
Brake system Spring and pneumatic lock type
Sensor cord length ø7-500 mm Oil-resistant
Stroke length tolerance Up to 250 mm:
+1.0
0
, 251 mm to 1000 mm
+1.4
0
Refer to pages 692 to 697 for cylinders with
auto switches.
•
Auto switch proper mounting position (detection
at stroke end) and its mounting height
•Operatingrange
•Minimumstrokeforautoswitchmounting
•Autoswitchmountingbrackets/Partno.
Mounting Basic
Axial
foot
Rod
flange
Head
flange
Single
clevis
Double
clevis
Center
trunnion
Standard
Rod end nut
V V V V V V V
Clevis pin — — — — —
V
—
Option
Single knuckle joint
V V V V V V V
Double knuckle joint
(with pin)
V V V V V V V
With rod boot
V V V V V V V