All reasonable efforts to ensure the accuracy of the information detailed in this flyer were
made at the time of publishing. However, SMC can in no way warrant the information herein
contained as specifications are subject to change without notice.
SMC Corporation of America
10100 SMC Blvd. Noblesville, IN 46060
(800) SMC.SMC1 (762-7621)
Fluid
Working pressure range
Ambient & Fluid Temperature
Lubrication
Pilot operator manual override
Enclosure
Port size
Cv factor
Actuator port
Rated voltage
Allowable voltage range
Coil insulation
Power consumption
Specifications
VFN2120N-5B-02N-X36 NAMUR Solenoid Valve Rotary Actuator Configuration
Reverse functionNormal function
5-way solenoid valve configuration (for Double acting actuator )
D-TYPE
B-TYPE
Left side port operationRight side port operation
3-way solenoid valve configuration (for Single acting actuator)
C-TYPE
A-TYPE
Solenoid is not energized
Port Pressurized
Port exhausted
Solenoid is energized
Note : Direction of rotary actuator may be
different from the picture, it depends
on the manufacturer of rotary actuator.
Air or inert gas
21.8psi to 130psi (0.15 to 0.9 MPa)
14°F to 140°F (–10°C to +60°C)
Not required
Locking type
IP67
1/4” NPT
0.8
NAMUR mount
24VDC & 110VAC
–15% to 10% of rated voltage
Class B
0.5W
How to Order
Voltage
3 110VDC
5 24VDC
Thread size
02 1/4”
VFN2120N
–
5B
–
02 N
X36A
3 port/5 port
A 3 port Port #4 on Coil side
B 5 port Port #2 on Coil side
C 3 port Port #2 on Coil side
D 5 port Port #4 on Coil side
Thread type
N NPT
NAMUR interface
Manual override
B Locking type (Tool required)
1. Controls the Butterfly Actuator Speed with greater accuracy by a
unique SMC Throttling Design
2. Namur mounting allows for installation between the Actuator and
SMC PPS Body Solenoid Valve or on a Delrin Sub-base
3. Will help reduce "water hammer" by throttling the actuator speed
allowing for more precise Actuator control
4. Stainless Steel adjustment screws
5. Designed to work with a variety of Actuator sizes
6. Stainless Steel or Anodized Aluminum options
7. Does not completely close off allowing the actuator to still function
if the operator leaves it in the closed speed condition
8. Captive "O" rings allow for overhead mounting to reduce seal loss
9. Ships as a "Kit" with S/S mounting screws
10. Installs easily in either Namur mounting position
Purpose of the throttle plate:
AXT842-30-24A
–
XO-RRD-2.5M
Dimension
VFN2120N-B-02N-X36A
LOCKING TYPE
M12 CONNECTOR
2xDUCK-BILL CHECK VALVE (3/5 PORT)
79
55.5
156.5
PORT 1
PORT 3
NPT, G1/4” SUP. PORT
23.523.5
PORT 5
PORT 4 PORT 2
24
37
MANUAL OVERRIDE OPERATION
SYMBOL
18.5
4123.5
9.4 33
25
14.5
1
37
24
2xUNF #10-32, M5x0.8 CAPTIVE
MOUNTING SCREW
21.5
(TOOL REQUIRED)