Standard Specifications
Valve construction
Fluid
Note 2)
Withstand pressure (MPa)
Ambient temperature (°C)
Fluid temperature (°C)
Environment
Valve leakage (cm
3
/min)
Mounting orientation
Vibration/Impact (m/s
2
)
Note 4)
Rated voltage
Allowable voltage fluctuation (%)
Coil insulation type
Enclosure
Power consumption (W)
Note 3)
Grommet / Tape winding
Faston terminal / Molded
Grommet / Molded
Valve specificationsCoil specifications
Direct operated poppet
Water (except waste water or agricultural water), Air, Low vacuum
2.0
–10 to 50
1 to 50 (No freezing)
Location without corrosive or explosive gases
0 (with water pressure) 1 or less (Air)
Unrestricted
30/150
±10% of rated voltage
Class B
Dust-proof (equivalent to IP40)
Dust-tight (equivalent to IP60)
Note 5)
Dust-tight / Low jetproof (equivalent to IP65)
2.5 (VDW10), 3 (VDW20/30)
24 VDC, 12 VDC, 6 VDC, 5 VDC, 3 VDC,
100 VAC, 110 VAC, 200 VAC, 220 VAC (50/60 Hz)
Note 1) When used under conditions which may cause condensation on the exterior of the product,
select Grommet / Molded.
Note 2) When used with deionized water, select “L” (Stainless steel, FKM) for the material type.
Note 3) Since the AC coil specification includes a rectifier element, there is no difference in power con-
sumption between inrush and holding.
In the case of 110/220 VAC, the VDW10 is 3 W and the VDW20/30 is 3.5 W.
Note 4) Vibration resistance ····· No malfunction when tested with one sweep of 5 to 200 Hz in the axial
direction and at a right angle to the armature, in both energized and
deenergized states.
Impact resistance ········ No malfunction when tested with a drop tester in the axial direction and
at a right angle to the armature, one time each in energized and
deenergized states.
Note 5) Since electrical connections are exposed, there is no water resistance.
Characteristic Specifications
Note 1) The maximum operating pressure differential changes depending on the flow direction of the
fluid. Refer to page 264 for details.
Note 2) For low vacuum specifications, the operating pressure range is 1 Torr (1.33 x 10
2
Pa) to 1.0
MPa.
Please consult with SMC if using below 1 Torr (1.33 x 10
2
Pa).
VDW10
VDW20
VDW30
Model
1
1.6
1.6
2.3
3.2
2
3
4
0.9
0.4
0.7
0.4
0.2
0.8
0.4
0.2
0.4
0.2
0.2
0.1
0.05
0.2
0.1
0.05
Orifice dia.
(mm ø)
Mass
(kg)
Port size
M5
M5
1/8 (6A)
1/8 (6A)
1/4 (8A)
Max. operating pressure
differential (MPa)
Note 1)
Pressure port 1 Pressure port 2
Operating
Pressure range
(MPa)
Note 2)
0.08
0 to 1.0
0.1
1/8: 0.23
1/4: 0.26
Flow Characteristics
VDW10
VDW20
VDW30
Model
1
1.6
1.6
2.3
3.2
2
3
4
N.C.
0.96
1.7
1.9
4.3
7.2
3.8
6.7
11
Av x 10
–6
m
2
0.04
0.07
0.08
0.18
0.30
0.16
0.28
0.44
Cv converted
0.04
0.07
0.09
0.18
0.33
0.16
0.30
0.46
Cv
0.40
0.25
0.45
0.45
0.38
0.52
0.52
0.49
b
0.14
0.30
0.31
0.58
1.2
0.52
1.0
1.5
C [dm
3
/(s·bar)]
1→2 (IN→N.C.)
Water Air
1→2 (IN→N.C.)
Orifice dia.
(mm ø)
Port size
M5
M5
1/8 (6A)
1/8 (6A)
1/4 (8A)
Oil-free specification
Lead wire length: 600 mm specification
Seal material: Kalrez
®
specification
Note)
Symbol Specifications
Made to Order
(For details, refer to page 259.)
X23
X60
X133
Non-leak (10
-6
Pa·m
3
/sec) /
Vacuum (0.1Pa·abs) specification
X22
Note) Kalrez
®
is a registered trademark of DuPont Dow
Elastomers.
Series VDW10/20/30
244
Made to
Order