VEX1 3 3
3
BA
B
F
G
N
M5 G
0
3
VEX1 3
B
F
G
N
10 G5
A
B
01
02
02
03
04
04
06
10
10
12
14
20
Nil
01
02
1
3
5
7
9
2
B
F
G
N
VEX1A33 VEX1B33 VEX113 VEX123 VEX133 VEX153 VEX173 VEX193
VEX1-18-1A
VEX1-18-2A
VEX1-18-1A
VEX1-18-2A
VEX3-32A
G27-10-R1-X207 G27-10-01 G36-10-01
AN120-M5
G46-10-01
VEX5-32A VEX7-32A VEX9-32A
0
3
0
3
0
3
0
3
0
3
0
3
Power Valve/Precision Regulator
How to Order
VEX13 Series
0
3
843
Regulator valve
Type
Precision regulator
Operation
Manual knob
Seal material
NBR seals
FKM seals
Nil
B
Note)
Refer to Applicable
Fluids on page 842.
Threads (1/8 only)
Nil
F
N
T
Rc
G
Note 1)
NPT
NPTF
Option
Bracket
Foot
Pressure gauge
Silencer
for bleed port
Body size Port size
Body ported
Base mounted
Body size
Port size
Port
M5
01
Nil
M5
01
1(P), 2(A), 3(R)
M5
Without sub-plate
M5
8
1
8
1
Regulator valve
Type
Precision regulator
Operation
Air operated type
Manual knob type
Body size Port size
Body size
Port
Port size
1(P), 2(A) 3(R)
Thread type
Nil
F
N
T
Rc
G
Note 1)
NPT
NPTF
Option
Bracket
Foot
Pressure gauge
Silencer
for bleed port
Body ported
Base
mounted
8
1
4
1
4
1
8
3
2
1
2
1
4
3
1
Without sub-plate
1
2
4
1
2
1
1
4
1
8
1
4
1
1
1
2
Option
(2)
Description
Bracket (With bolt and washer)
Foot (With bolt and washer)
Pressure gauge
(3)
Silencer for bleed port (PE)
Part no.
Note 1) Not conforming to ISO1179-1.
Note 2) The optional parts are shipped in the same package.
Note 3) If a pressure gauge other than that which is indicated in the option table is to be used, also enter the part number of the pressure gauge.
Refer to the pressure gauge guide in Best Pneumatics No. 7 for details.
Example: VEX1333-03
G36-4-01
Caution
Using the External Pilot
1. If a pressure difference over 0.1 MPa between
the supply and the set pressure cannot be
maintained, change to an external pilot to
obtain the necessary pressure difference.
2. If a mist separator cannot be installed on the
supply side, change to an external pilot, and
make sure to install a mist separator on the
pilot side.
•ForVEX13 (NBR seals)
Fixed orifice assembly (with O-ring) part no.:
VEX1-A30-3
•ForVEX133B(FKMseals)
Fixed orifice assembly (with O-ring) part no.:
VEX1-A30-3B
Note) O-rings cannot be shipped as a single unit.
How to Switch to External Pilot
1. Using a flat head screwdriver, remove the
fixed orifice from port P1.
2. Install the fixed orifice facing in the opposite
direction (external pilot). Install it carefully
to prevent damage to the O-ring.
3. Tighten the fixed orifice again and connect
the pilot piping to port P1 using an M5
fitting.
Position for port P1
Dimensions of port P1
<Internal pilot>
<External pilot>
Port P1
Fixed orifice
Fittings for M5
A
B