Caution
How to Order
qMake sure all contacts are secure.
wVoltage should be held within the allowable
voltage range.
Specifications
How to calculate flow rate
Refer to p.0-36 for flow rate calculations.
DIN Connector (Wiring)
Power Source and Wiring
Interface Regulator Specifications
VS7 6
FG
YZ
∗
FHG
FJG
FPG
FIG
∗
∗ Option
∗ If specifying more than
one symbol, indicate them
in the alphabetical order.
S
D
Single
Double
1
2
3
4
9
100V AC
200V AC
24V DC
12V DC
Others
(250V or less)
—
N
None
Indicator light
—
0
Connector
W/o connector
Symbol
Number of solenoid
Rated voltage
Option
Port size of sub-plate
Connector
M
Direct manual override
Z
Indicator light with surge
voltage suppressor
Wedge packing style with
direct manual override
MR
R
Wedge packing style
Individual pilot EXH
V
—
A02
A03
B02
B03
Without sub-plate
Side piping
Side piping
Bottom piping
Bottom piping
1
4
3
8
1
4
3
8
3
8
∗ R port:
FG S 1
∗
∗
E
Rc (PT)
F G (PF)
N
NPT
T NPTF
Thread
Ordering source area code
E
Europe
N North America
-
Code
Japan, Asia
Australia
areas
Contact SMC
for other voltages (9)
Order
Made
Protective class
class I (Mark: )
Q
Be sure to read before handling. Refer to p.0-33 to 0-36 for Safety Instructions and common
precautions.
Interface regulator model
Applicable solenoid valve
Regulation port
Max. operating pressure
Setting pressure range
Ambient and fluid temperature
Pressure gauge port size
Weight (kg)
Air supply side eff area (mm
2
)
S (P=0.7MPa, P1=0.5MPa)
Air exhaust side eff area
S (P2=0.5MPa)
P A
P B
A EA
B EB
ARB250
VS7-6
AB P
1.0MPa
(1)
0.1 to 0.83MPa
(1)
5 to 60
o
C
(3)
1
8
0.55
16
16
13
11
15
16
25 mm
2
18 mm
2
Note 1) Maximum operating pressure of solenoid valve is 0.9 MPa.
Note 2) Be sure to set pressure within setting pressure range of the solenoid valve.
Note 3) Solenoid valve: Max. 50
o
C
Note 4) Synthesized effective area with 2 position single style solenoid valve.
Note 5) •Supply pressure to interface regulator only from P port except when it is used with reverse
pressure style valve.
•Use the ARB210 or ARB310 model to combine a pressure centre valve and the A and B port
pressure reduction of a spacer style regulator.
•Use the ARB210 or ARB310 model to combine a reverse pressure valve and a spacer style
regulator. The P port pressure reduction cannot be used.
•To use a perfect valve and a spacer style regulator, use a manifold or a sub plate as the standard
and stack in the following order: the perfect spacer, spacer style regulator, and the valve.
•When a closed centre valve is combined with the A and B port pressure reduction of a spacer style
regulator, it cannot be used for intermediate stops of the cylinder because of the leakage from the
relief port of the regulator.
Note:
Manifold exploded view see page 1.19-33
for details.
1.19-3