001 LHRZ
How to Order
Thermo-chiller
Series HRZ
Fluorinated Fluid Type
Fluorinated Fluid Type
Cooling capacity
Symbol
001
002
004
008
Cooling capacity
1 kW
2 kW
4 kW
8 kW
Temperature range setting
–20 to 40°C
20 to 90°C
–20 to 90°C
1 kW
—
2 kW
4 kW
—
8 kW
Symbol
L
H
W
Temperature range setting
Specifications (For details, please consult our “Product Specifications” information.)
None
Analog communication
DeviceNet
™
communication
NPT fittings
Circulating fluid automatic recovery
Nil
C
D
N
Z
Option (Refer to pages 98 and 99.)
Note 1) It should have no condensation.
Note 2) Fluorinert
TM
is a trademark of 3M and GALDEN
®
is a registered trademark of Solvay Solexis, Inc. Regarding the fluid other than the above, please contact SMC.
Note 3) (1) Facility water temperature: 25°C, (2) Circulating fluid flow rate: Values at circulating fluid rated flow rate. Values common for 50/60 Hz.
Note 4) Thermo-cooler specifications do not have heating capability.
Note 5) Capacity of the Thermo-chiller outlet when the circulating fluid temperature is at 20°C.
Note 6)
Required flow for cooling capacity or maintaining the temperature stability. When used below the rated flow, use the individually sold, “By-pass piping set” (Refer to page 95).
Note 7) Minimum volume required for operating only the Thermo-chiller. (Circulating fluid temperature: 20°C, including the Thermo-chiller’s internal pipings or heat exchanger)
Note 8) Preliminary space volume without main tank capacity. Available for collecting the circulating fluid inside an external piping or for preliminary injection.
Note 9) Required flow when a load is applied as shown in the cooling capacity when the facility water temperature is at 25°C.
Note 10) Mass in the dry state without circulating fluids.
Model
HRZ001-L
Cooling method
Refrigerant
Control system
Ambient temp./humidity
Note 1)
Circulating fluid
Note 2)
Temp. range setting
Note 1)
(°C)
Cooling capacity
Note 3)
(kW)
Heating capacity
Note 3)
(kW)
Temp. stability
Note 4)
(°C)
Rated flow
Note 6)
(
l/min)
Main tank capacity
Note 7)
(l )
Sub-tank capacity
Note 8)
(l )
Port size
Wetted parts material
Temperature range (°C)
Pressure range (MPa)
Required flow
Note 9)
(50/60 Hz) (l /min)
Port size
Wetted parts material
Power supply
Breaker capacity (A)
Rated current (A)
Alarm
Communications
Pump capacity
Note 5)
(50/60 Hz)
(MPa)
Mass
Note 10)
(kg)
Safety standards
HRZ002-L HRZ004-L HRZ008-L HRZ001-H HRZ002-H HRZ004-H HRZ008-H HRZ002-W HRZ008-W
Water-cooled refrigeration
R404A (HFC)
PID control
Temperature: 10 to 35°C, Humidity: 30 to 70%RH
20
Approx. 15
Approx. 16
30
Approx. 22
Approx. 17
20
Approx. 12
Approx. 15
Rc 3/4
Stainless steel, EPDM, Copper brazing (Heat exchanger), PPS, Silicone, Fluororesin
10 to 25
0.3 to 0.7
Rc 1/2
Stainless steel, EPDM, Copper brazing (Heat exchanger), Silicone, Brass
3-phase 200 VAC 50 Hz, 3-phase 200 to 208 VAC 60 Hz Allowable voltage fluctuation ±10%
Refer to page 94.
Contact input/output (D-sub 25 pin) and Serial RS-485 (D-sub 9 pin) (Refer to pages 92 and 93.)
UL, CE marking, SEMI (S2-0703, S8-0701, F47-0200), SEMATECH (S2-93, S8-95)
30
20 25
60
46
170 175 275 145 170
20
14
30
23
5/5 6/6 15/22 18/23 3/4 5/6 9/10 13/14 6/7 13/14
Approx. 15
Approx. 16
±0.1
–20 to 40 20 to 90 –20 to 90
1.0
(at –10°C)
0.45/0.65 (at 20 l/min) 0.45/0.65 (at 20 l/min)
0.65/0.95
(at 30 l/min)
0.40/0.60
(at 20 l/min)
Fluorinert
TM
FC-3283/GALDEN
®
HT135 Fluorinert
TM
FC-40/GALDEN
®
HT200
• –20 to 40°C: Fluorinert
TM
FC-3283/GALDEN
®
HT135
• 20 to 90°C: Fluorinert
TM
FC-40/GALDEN
®
HT200
2.0
(at –10°C)
1.0
(at 20°C)
2.0
(at 20°C)
4.0
(at 20°C)
8.0
(at 20°C)
2.0
(at 20°C)
8.0
(at 20°C)
4.0
(at –10°C)
8.0
(at –10°C)
2.8
(at –10°C)
3.2
(at –10°C)
2.3
(at 20°C)
2.6
(at 20°C)
2.8
(at 20°C)
3.0
(at 20°C)
2.3
(at 20°C)
3.3
(at 20°C)
3.6
(at –10°C)
5.9
(at –10°C)
Circulating fluid system
Cooling water system
Electrical system
80