Action
Fluid
Proof pressure
Maximum operating pressure
Minimum operating pressure
Ambient and fluid temperature
Lubrication
Piston speed
Stroke length tolerance
Cushion
Mounting
Rod end configuration
Allowable rotational torque
Rod non-rotating accuracy
Double acting, Single rod
Air
1.05 MPa
0.7 MPa
0.05 MPa
–10 to 60°C
Not required (Non-lube)
50 to 500 mm/s
Rubber bumper
Foot, Rod flange, Head flange, Single clevis, Double clevis
Rod end male thread, Rod end female thread
+1.4
0
Size
Bore size (mm)
Standard stroke (mm) Maximum manufacturable stroke
±1°±0.8°
0.25 N·m 0.55 N·m 1.25 N·m 2.0 N·m
25 32 40 50 63
(mm)
25, 32, 40
50, 63
5, 10, 15, 20, 25, 30, 35, 40, 45, 50
75, 100, 125, 150, 175, 200, 250, 300
300
∗ Other intermediate strokes can be manufactured upon receipt of order. Please contact SMC.
∗∗ Strokes longer than 300 mm are not available.
Specifications
Standard Stroke
±0.5°
2
Plate Cylinder: Double Acting, Single Rod
Series MU
Bore size
MU25
MU32
MU40
MU50
MU63
Thread size
M5 x 0.8
M6 x 1
M8 x 1.25
M10 x 1.5
M12 x 1.75
Tightening torque (N·m)
4.9 to 5.9
8.28 to 10.12
19.8 to 24.2
39.6 to 48.4
68.4 to 83.6
Foot
Note 1)
Flange
Single clevis
Double clevis
Note 3)
25
MU-L02
MU-F02
MU-C02
MU-D02
32
MU-L03
MU-F03
MU-C03
MU-D03
40
MU-L04
MU-F04
MU-C04
MU-D04
50
MU-L05
MU-F05
MU-C05
MU-D05
63
MU-L06
MU-F06
MU-C06
MU-D06
Size
Mounting bracket
Note 1) When ordering foot bracket, order 2 pieces per cylinder.
Note 2) Accessories for each mounting bracket are as follows.
Foot/Flange/Single clevis: Body mounting bolt
Double clevis: Clevis pin, Type C retaining ring for axis, Body mounting bolt
Note 3) Clevis pin and retaining ring are shipped together with double clevis.
Note 4) The tightening torque for body mounting bolts is shown in the below table.
Note 5) The application of a locking agent (Example: Loctite
®
242) to body mounting bolts is
recommended.
Mounting Bracket/Part No.
Recommended Tightening Torque for Mounting Bracket on Body