Series SYJ3000
SYJ3 3 5 M
SYJ3 4 M
2
2
1
2
3
4
5
2 position single solenoid
2 position double solenoid
3 position closed center
3 position exhaust center
3 position pressure center
5
0
0
SYJ3 2 5 M1 M30
5
6
V
S
R
24 VDC
12 VDC
6 VDC
5 VDC
3 VDC
1
2
3
4
100 VAC
200 VAC
110 VAC [115 VAC]
220 VAC [230 VAC]
For manifold type
31, S31, 32, S32
5 port
(Type 20 Manifold)
Body ported
Base mounted
(4 port)
Base mounted
(5 port)
5 port
For sub-plate,
manifold type 41, S41, 46, S46
4 port
Port size
Nil: Without sub-plate
(With gasket and screws)
M5: With M5 port sub-plate
Manual override
Nil: Non-locking push type
D:
Push-turn locking slotted type
E:
Push-turn locking lever type
Type of actuation
Nil
S
Z
R
U
Without light/surge voltage suppressor
With surge voltage suppresor
With light/surge voltage suppressor
With surge voltage suppressor (Non-polar type)
With light/surge voltage suppressor (Non-polar type)
Light/surge voltage suppressor
Bracket
Body option
Rated voltage
DC
AC (
50
/60 Hz)
Electrical entry
∗ LN, MN type: with 2 sockets.
∗ For connector cable of M8 connector, refer to back page 10.
Note 1) Enter the cable length symbols in 쏔. Please be sure
to fill in the blank referring to back page 10.
24, 12, 6, 5, 3 VDC
100,110, 200, 220 VAC
Grommet
L plug connector
M plug connector
(Manifold use only)
Nil
T
Standard
With power saving circuit
(24, 12 VDC only)
Coil specifications
24, 12, 6, 5, 3 VDC
M8 connector
Note) When placing an order for body ported
solenoid valve as a single unit, mounting
bolt for manifold and gasket are not
attached. Order them separately, if
necessary. (For details, refer to page 15.)
How to Order
+
–
+
–
+
–
+
–
+
–
+
–
∗ For type W쏔, DC voltage is only available.
∗
For AC voltage valves there is no “S” option.
It is already built-in to the rectifier circuit.
∗
For type “R” and “U”, DC voltage is only
available.
∗
Power saving circuit is only available in the
"Z" type.
Single Double
-+
0: Pilot valve individual
exhaust for the pilot
valve
3: Common exhaust type
for main and pilot valve
∗ Power saving circuit
is not available in the
case of W쏔 type.
G: Lead wire
length 300 mm
H: Lead wire
length 600 mm
L:
With lead wire
(Length 300 mm)
LN: Without
lead wire
M:
With lead wire
(Length 300 mm)
LO: Without
connector
MN: Without
lead wire
WO: Without
connector cable
MO: Without
connector
Nil: Without bracket
F: With bracket
∗ Brackets cannot
be retrofitted.
Note) • The double solenoid mounting
bracket is supplied unattached.
• To order the double solenoid
bracket for use with a single
solenoid valve, order the single
solenoid valve without a bracket
and order the bracket (VJ3000-
13-1) separately.
(Example) SYJ3120-5M-M3
VJ3000-13-1
W쏔: With connector
cable
Note 1)
3
R port P, E port R port P, E port