05
07
10
13
15
0.5 mm
0.7 mm
1.0 mm
1.3 mm
1.5 mm
Nozzle diameter
J
K
A
B
P3
P5
Q3
Q5
Nil
Supply valve (N.C.)
Supply valve (N.C.), and release valve
Supply valve (N.O.)
Supply valve (N.O.), and release valve
Air operated valve (supply valve), Port size connection M3 x 0.5
Air operated valve (supply valve), Port size connection M5 x 0.8
Air operated valve (supply/release valve), Port size connection M3 x 0.5
Air operated valve (supply/release valve), Port size connection M5 x 0.8
Without valve
Supply valve/Release valve combination
DC: 1 W (With indicator light: 1.05 W)
DC: 0.45 W (With indicator light: 0.5 W)
Nil
Y
Pilot valve
Nil
A
Side/Bottom entry
Side entry
Vacuum port location
Vacuum switch electrical entry
Nil
L
C
CL
CN
Nil
L
Grommet type, with 0.6 m lead wire (ZSE1)
Grommet type, with 3 m lead wire (ZSE1)
Connector type, with 0.6 m lead wire (ZSE1)
Connector type, with 3 m lead wire (ZSE1)
Connector type, without connector assembly
Grommet type, with 0.5 m lead wire (ZSM1)
Grommet type, with 3 m lead wire (ZSM1)
Light/Surge voltage suppressor
Nil
Z
S
None
With light/surge voltage suppressor
With surge voltage suppressor
Vacuum switch model
Nil
E14
E15
E16
E17
E18
E19
E55
M15
M21
Without switch
1 output, without analog output, 3 rotation setting (ZSE1)
1 output, without analog output, 200° setting (ZSE1)
2 outputs, without analog output, 3 rotation setting (ZSE1)
2 outputs, without analog output, 200° setting (ZSE1)
1 output, analog output, 3 rotation setting (ZSE1)
1 output, analog output, 200° setting (ZSE1)
1 output, without analog output, 200° setting, PNP output (ZSE1)
1 output, without analog output, Diaphragm (18 rotation setting), Solid state(10 to 26 VDC) (ZSM1)
1 output, without analog output, Diaphragm (18 rotation setting), Reed (AC/DC 100 VAC)(ZSM1)
G
H
L
LN
LO
Nil
Grommet type, with 0.3 m lead wire (applicable to DC)
Grommet type, with 0.6 m lead wire (applicable to DC)
L plug connector, with 0.3 m lead wire
L plug connector, without lead wire (applicable to DC)
L plug connector, without connector (applicable to DC)
Air operated/Without valve
Electrical entry
Manual override
Nil
B
Non-locking push type
Locking slotted type
1
Note)
3
Note)
5
6
V
S
R
Nil
100 VAC 50/60 Hz
110 VAC 50/60 Hz
24 VDC
12 VDC
6 VDC
5 VDC
3 VDC
Air operated/Without valve
Solenoid valve rated voltage
ZM
Single unit: With valve + With standard silencer
Single unit: With valve + With high noise reduction silencer
Manifold: With common SUP valve
Manifold: With individual SUP valve
Single unit: With standard silencer (Without valve)
Single unit: With high noise reduction silencer (Without valve)
Manifold: Without common SUP valve
Manifold: Without individual SUP valve
Body style
0.35 MPa
0.45 MPa
0.5 MPa
H
Standard supply
pressure
∗Refer to table 1 for
the selection of
standard supply
pressure and
nozzle size.
Nil
T
Rc
NPTF
G
Note)
F
Thread type
Note) G thread
The thread ridge shape is
compatible with the G
thread standard (JIS
B0202), but other shapes
are not conforming to
ISO16030 and ISO1179.
∗As the double solenoid specifications, -X126 and -X135 are available as a special
order. (Refer to page 1006.)
When selecting air operated valves, there will be no symbol specified for “pilot
valves”, “solenoid valve rated voltage”, “electrical entry”, “light/surge voltage
suppressor” and “manual override”.
∗S is not available for AC.
DC voltage (with surge voltage suppressor)
If the polarity is incorrect at DC (surge voltage suppressor), diode or
switching element may be damaged.
Note) CE compliant products are not
available for “1” and “3”.
∗ Only 24 VDC and 12 VDC are
applicable to 0.45 W.
1
1S
3
Note)
5
Note)
2
2S
4
Note)
6
Note)
S (0.45)
—
—
—
M (0.35)
—
—
H (0.5)
—
0.5 mm
0.7 mm
1.0 mm
1.3 mm
1.5 mm
Nozzle
diameter
Standard supply pressure MPa
Combination of Nozzle Diameter and Standard Supply Pressure
Note) When the product is used for the manifold,
the exhaust air of the operating ejector
may enter the vacuum (V) port of the non-
operating ejector and be released if there
are an operating and non-operating ejec-
tor. If this becomes a problem, consider
using a double check valve (-X107 on
page 1004) or individual exhaust (-X111
on page 1005.)
M
S
Made to Order
Refer to pages 1004 to 1006 for details.
Release flow rate
adjusting needle
Nil
L
Without lock nut
With lock nut
Compatible with release valves only.
L
CE compliant
Nil
Q
—
CE compliant
CE compliant
—
—
—
986
How to Order
Vacuum Ejector
With Valve and Switch
Series ZM
[Option]
Note) CE compliant: For
DC only.