qw
How to Order
Electric Actuator/Rod Type
LEY16, 25, 32
Series LEY
LEY
16
30
B 11 6N
16
25
32
Nil
R
L
D
Top mounting type
Right side parallel type
Left side parallel type
In-line type
A
B
C
LEY16
10
5
2.5
LEY25
12
6
3
LEY32
16
8
4
Symbol
30
500
to
to
∗ Refer to the applicable stroke table.
∗ Applicable stroke table
LEY16
LEY25
LEY32
P
P
P
Stroke [mm]
Model
30
P
P
P
50
P
P
P
100
P
P
P
150
P
P
P
200
P
P
P
250
P
P
P
300
—
P
P
350
—
P
P
400
—
—
P
450
—
—
P
500
Nil
C
B
Without option
With motor cover
With lock
∗2
Nil
M
Rod end female thread
Rod end male thread
(1 rod end nut is included.)
30
500
∗1 When [With lock] is selected, [With motor
cover] cannot be selected.
∗2 For 30 stroke or less of size 16 with [Motor
mounting position: Top mounting type or
right/left side parallel type], when [With lock] is
selected, the motor projects through the end of
the body.
Select after confirming interface with such as
work pieces.
Nil
A
P
P
P
P
P
—
Symbol Type
Size
Step motor
(Servo/24 VDC)
Servo motor
Note 1)
(24 VDC)
Compatible
controller
LECP6
LECP1
LECA6
LEY16 LEY25 LEY32
Refer to pages 17 and 18 for auto switches.
S
q w e r t y u i o !0 !1 !2 !3
10 to 300
15 to 400
20 to 500
Manufacturable
stroke range
[mm]
∗ Consult with SMC for the manufacture of intermediate strokes other than those specified on the above.
q
Size r Lead [mm]
t Stroke [mm]
y Motor option
∗1
u Rod end thread
w Motor mounting position
e Motor type
Step Motor (Servo/24 VDC)
Servo Motor (24 VDC)
Note 1) CE-compliant products
q EMC compliance was tested by combining the electric
actuator LEY series and the controller LEC series. The
EMC depends on the configuration of the customer’s
control panel and the relationship with other electrical
equipment and wiring. Therefore conformity to the EMC
directive cannot be certified for SMC componentsincorpo-
rated into the customer’s equipment under actual
operating conditions. As a result it is necessary for the
customer to verify conformity to the EMC directive for the
machinery and equipment as a whole.
w For the servo motor (24 VDC) specification, EMC
compliance was tested by installing a noise filter set
(LEC-NFA). Refer to page 47 for the noise filter set. Refer
to the LECA Operation Manual for installation.
Caution
Confirm that the combination of the controller and the actuator is correct.
The actuator and controller are sold as a package. (Controller → Pages 39 and 51)
<Check the following before use.>
q Check that actuator label for model number. This matches the controller.
w Check Parallel I/O configuration matches (NPN or PNP).
∗
Refer to the operation manual for using the products. Please download it via our website. http://www.smcworld.com