DeviceNet
™
EX600 integrated-type (I/O) serial transmission system (Fieldbus system)
PROFIBUS DP
CC-Link
EtherNet/IP
™
PROFINET
EtherCAT
AABABABABABA
Base Mounted
How to Order Manifold
VQC1000 Series
·····
Enter EX250-compliant S kit only.
Enter EX600-compliant S kit only.
······ ··········
······
VV5QC 1 1
08
SDQ
Base mounted plug-in
VQC1000 series
01 1 station
C6
VV5QC 1 1
08
FD1
C6
PNP sensor input or without input block
NPN sensor input
Nil
N
Note) For the S kit compatible with AS-Interface, the
maximum number of stations is limited. Refer to
page 805 in Best Pneumatics No. 1-1 for details.
Nil
Without SI unit/input block (SD0)
Without input block
With 1 input block
With 8 input blocks
0
1
8
Note 1) Without SI unit, the symbol is nil.
Note 2) SI unit is not included in I/O unit stations.
Note 3) When I/O unit is selected, it is shipped
separately, and assembled by customer. Refer
to the attached operation manual for mounting
method.
Nil
None
1 station
9 stations
1
9
Nil
Without input block
M12, 2 inputs
M12, 4 inputs
M8, 4 inputs (3 pins)
1
2
3
T
·······
kit
·
F
·
P
·
S
·······
kit
ML
Nil
2
3
Without end plate
M12 connector power supply (Max. supply current 2A)
7/8 inch connector power supply (Max. supply current 8A)
Note) Without SI unit, the symbol is nil.
Nil
None
All stations with back pressure check valve
With DIN rail (Rail length: Standard)
Note 7)
With DIN rail (Rail length: Special)
Note 7)
Special wiring spec. (Except double wiring)
With name plate
External pilot
Direct EXH outlet with built-in silencer
B
Note 2)
D
D
Note 3)
K
Note 4)
N
Note 10)
R
Note 5)
S
Note 6)
Note 1) When two or more symbols are specified,
indicate them alphabetically. Example: -BRS
Note 2) When a back pressure check valve is desired,
and is to be installed only in certain manifold
stations, specify the mounting position by
means of the manifold specification sheet.
Note 3) For special DIN rail length, indicate “D”.
(Enter the number of stations inside .)
Example: -D08
In this case, stations will be mounted on a DIN
rail for 8 stations regardless of the actual num-
ber of manifold stations.
The specified number of stations must be larg-
er than the number of stations on the manifold.
Indicate “-D0” for the option without DIN rail.
Note 4) When single wiring and double wiring are
mixed, specify wiring type of each station by
means of the manifold specification sheet.
Note 5) For external pilot option, “-R”, indicate the ex-
ternal pilot specification “R” for the applicable
valves as well.
Note 6) Built-in silencer type does not satisfy IP67.
Note 7) When “Without SI unit (SD0, SD60)” is speci-
fied, “With DIN rail (D)” cannot be selected.
Note 8) When changing the specifications of the EX600
from no DIN rail to DIN rail mounting, please
consult SMC.
Note 9) DIN rail is not attached (but shipped together)
on the manifold in case of the EX600 with DIN
rail. Refer to back page 597 for mounting
method.
Note 10) When mounting the blanking plate with con-
nector and the slide locking manual type
valve by ordering only the manifold, order the
name plate separately. For details, refer to
page 589.
C3
C4
C6
M5
CM
L3
L4
L6
L5
B3
B4
B6
B5
LM
MM
Note 2)
With ø3.2 One-touch fitting
With ø4 One-touch fitting
With ø6 One-touch fitting
M5 thread
Mixed sizes and with port plug
Top ported elbow with ø3.2 One-touch fitting
Top ported elbow with ø4 One-touch fitting
Top ported elbow with ø6 One-touch fitting
M5 thread
Bottom ported elbow with ø3.2 One-touch fitting
Bottom ported elbow with ø4 One-touch fitting
Bottom ported elbow with ø6 One-touch fitting
M5 thread
Elbow port, mixed sizes (Including upward, downward piping and mixed)
Mixed size for different types of piping, option installed
Note 1) Indicate the size by means of the manifold
specification sheet in case of “CM”, “LM”, “NM”.
Note 2) When selecting the mixed size for different types
of piping or dual flow fitting assembly, enter “MM”
and give instructions in the manifold specification
sheet.
Note 3) Symbols for inch sizes are as follows:
N1: ø1/8" N3: ø5/32"
N7: ø1/4" NM: Mixed
The top ported elbow is LNand
the bottom ported elbow is BN.
Plug-in Unit
···
···
The maximum number of stations differs depending on
the electrical entry. (Refer to Kit type/Electrical
entry/Cable length.)
Note)
In case of compatibility with the S kit/AS-Interface, the
maximum number of solenoids is as shown below, so
please be careful of the number of stations.
•8in/8out:Maximum8solenoids
•4in/4out:Maximum4solenoids
······ ······
······
······
D side Stations
···
1
···
2
···
3
···
4
···
5
···
6
···
7
···
8
···
n U side
∗
Stations are counted from station 1 on the D-side.
Valve stations
Input block specification
(Enter EX250-compliant S kit only.)
Number of input blocks
(Enter EX250-compliant S kit only.)
I/O unit stations
(Enter EX600-compliant S kit only.)
Input block type
(Enter EX250-compliant S kit only.)
∗ Select “Nil” for without SI unit (SD0).
Nil
EX250 integrated-type (I/O) serial transmission system
SI unit
output polarity
Positive common
Negative common
N
Nil
DeviceNet
™
—
AS-Interface
—
CANopen
—
PROFIBUS DP
—
CC-Link
—
EtherNet/IP
™
—
SI unit
output polarity
Positive common
Negative common
N
SI unit output polarity
End plate type
(Enter EX600-compliant S kit only.)
Option
Cylinder port size
Nil
DeviceNet
™
EtherNet/IP
™
—
DeviceNet
™
EX500 Gateway Decentralized
System (64 points)
EX500 Gateway
Decentralized System 2
(128 points)
EX260 integrated-type (for output)
serial transmission system
EX126 integrated-type
(for output) serial
transmission system
EtherNet/IP
™
EtherNet/IP
™
EtherCAT
PROFIBUS DP
PROFIBUS DP
PROFINET
CC-Link
CC-Link
—
SI unit
output polarity
Positive common
Negative common
N
544
A