20
How to Order
A
HRSH
090
Power supply
20
3-phase 200 VAC (50 Hz)
3-phase 200 to 230 VAC (60 Hz)
40
3-phase 380 to 415 VAC (50/60 Hz)
Pipe thread type
Nil
Rc
F
G (with Rc-G conversion fitting)
N
NPT (with Rc-NPT conversion fitting)
Cooling method
A
Air-cooled refrigeration
Nil
None
B
Note 1)
With earth leakage breaker
J
With automatic fluid fill function
M
Applicable to deionized water piping
S
Note 2)
Conforming to CE/UL standards
¡When multiple options are combined, indicate symbols in
alphabetical order.
Note 1) 200 V type only.
400 V type is provided with an earth leakage breaker as
standard.
Note 2) 200 V type only. 400 V type is CE-compliant as standard.
Additionally, combination with option B is not necessary.
An earth leakage breaker is equipped as standard.
Option
Thermo-chiller
Air-cooled 200 V/400 V Type
Inverter Type
HRSH090 Series
Cooling capacity
090
9.5 kW
Specifications
Model
HRSH090-Al-20-l HRSH090-Al-40-l
Cooling method Air-cooled refrigeration
Refrigerant R410A (HFC) (GWP1975)
Refrigerant charge kg 1.32
Control method PID control
Ambient temperature/humidity
Note 1), 9)
°C/% 5 to 45/30 to 70%
Circulating fluid system
Circulating fluid
Note 2)
Tap water, 15% Ethylene glycol aqueous solution, Deionized water
Set temperature range
Note 1)
°C 5 to 40
Cooling capacity
Note 3), 9)
kW 9.5
Heating capacity
Note 4)
kW 2.5
Temperature stability
Note 5)
°C
±0.1
Pump
capacity
Rated flow (Outlet) L/min 45 (0.5 MPa)
Maximum flow rate L/min 60
Maximum pump head m 50
Settable pressure range
Note 6)
MPa 0.1 to 0.5
Minimum operating flow rate
Note 7)
L/min 20
Tank capacity L 18
Circulating fluid outlet, circulating fluid return port
Rc1 (Symbol F: G1, Symbol N: NPT1)
Tank drain port Rc1/4 (Symbol F: G1/4, Symbol N: NPT1/4)
Fluid contact material
Stainless steel, Copper (Heat exchanger brazing), Brass, Bronze, Carbon, Ceramic,
PE, PVC, POM, PTFE, NBR, EPDM, FKM, PP
Electrical system
Power supply
3-phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz)
Allowable voltage range ±10%
(No continuous voltage fluctuation)
3-phase 380 to 415 VAC (50/60 Hz)
Allowable voltage range ±10%
(No continuous voltage fluctuation)
Applicable earth
Note 8)
leakage breaker
Rated current
A 30 20
Sensitivity of leak current
mA 30
Rated operating current
Note 5)
A 15 8
Rated power consumption
Note 5)
kW (kVA) 4.6 (5.2) 5.0 (5.6)
Noise level (Front 1 m/Height 1 m)
Note 5)
dB (A) 66
Accessories
Alarm code list stickers 2 pcs. (English 1 pc./Japanese 1 pc.),
Operation Manual (for installation/operation) 2 pcs. (English 1 pc./Japanese 1 pc.),
Y-strainer (40 meshes) 25A, Barrel nipple 25A, Anchor bolt fixing brackets 2 pcs. (including 4 M10 bolts)
Note 10)
Weight (dry state) kg Approx. 130
Note 1) Use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature and/or circulating fluid temperature is 10°C or less.
Note 2) Use fluid in condition below as the circulating fluid.
Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994)
15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.
Deionized water: Electric conductivity 1 μS/cm or higher (Electric resistivity 1 MΩ·cm or lower)
Note 3) q Ambient temperature: 32°C, w Circulating fluid: Tap water, e Circulating fluid temperature: 20°C, r Circulating fluid flow rate: Rated flow, t Power supply: 200/400 VAC
Note 4) q Ambient temperature: 32°C, w Circulating fluid: Tap water, e Circulating fluid flow rate: Rated flow, r Power supply: 200/400 VAC
Note 5) q Ambient temperature: 32°C, w Circulating fluid: Tap water, e Circulating fluid temperature: 20°C, r Load: Same as the cooling capacity,
t Circulating fluid flow rate: Rated flow, y Power supply: 200/400 VAC, u Piping length: Shortest
Note 6) With the pressure control mode by inverter. When the pressure control mode is not used, the pump power frequency set mode can be used.
Note 7) Fluid flow rate to maintain the cooling capacity. If the actual flow rate is lower than this, install a bypass piping.
Note 8) To be prepared by user. A specified earth leakage breaker is installed for option B [With earth leakage breaker], option S [Conforming to CE/UL standards] and 400 V type.
Note 9) If the product is used at altitude of 1000 m or higher, refer to “Operating Environment/Storage Environment” (page 151) Item 14 “* For altitude of 1000 m or higher”.
Note 10) The anchor bolt fixing brackets (including 4 M10 bolts) are used for fixing to wooden skids when packaging the thermo-chiller. No anchor bolt is included.
RoHS
(400 V type only)
(Option S only)
(UL Standards)
(Option S only)
138
A